BALDOR MICROFLEX SPECIFICATIONS |
| |
FMH2A03TR-xNx3 |
FMH2A06TR-xNx3 |
FMH2A09TR-xNx3 |
|
Min/Max AC Supply |
1 or 3 phase 105-230 VAC 50/60 Hz |
| Nominal DC Bus Supply |
160 -325 VDC |
| Cont/Peak Current |
3/6 Amps (3 secs.) |
6/12 Amps (3 secs.) |
9/18 Amps (3 secs.) |
|
Digital Inputs |
Two Inputs: Enable, Reset (software configurable) - opto-isolated
(10-30 VDC) |
| Digital Outputs |
One Output: Drive OK - opto-isolated |
|
50 mA per channel, 350 mA max. source per channel. 500 mA
max for 3 channels |
| Analog Command Input |
±10 V with 12-bit ADC resolution. Programmable for torque or velocity
command |
| Step and Direction Input |
Single ended % V TTL 400 MHz max. frequency |
| Feedback |
Digital interface programmable for: incremental encoder with encoder
loss detection. Max. frequency 10 MHz; Commutating incremental encoder; 17-bit synchronous srial interface (SSI) with
7 wire interface; Hall sensor (no encoder for trapezoidal commutation. Optional resolver feedback interface. |
| Encoder Output |
Simulated encoder output for connection to external motion
controller |
| Commutation |
Sinusoidal commutation with resolver, encoder or SSI feedback |
|
Trapezoidal commutation with Hall sensors only |
| Modes of Operation |
Torque control, velocity control, or step and direction |
| Communications |
RS232 or RS485 for commissioning and diagnostics |
| Protection |
DC bus over voltage monitoring; DC bus under voltage monitoring; Peak over current; Motor
short circuit; Over temperature; 12t over current |
|
Regenerative Capability |
Regeneration braking IGBT - requires external regen
resistor |
| Control Supply Input |
24 VDC nominal (20-30 VDC) @ 2 A external (4 A power on surge) -
customer supplied |
| Connectors |
D-type for serial port and feedback. Two part terminals for motor and power |
| Indicators |
Single LED indicator for drive status |
| Dimensions & Weights |
See link below |
|
Operating Temperature |
0°C to 45°C |